MONITOR HEATING SYSTEM
Section
5:
Troubleshooting
GF200 Resistance Values
COMPONENT
Ignition Transformer (connector E/E)
Power Transformer
(1)-Primary
(AC
120V)
Power Transformer
(l)-Secondary
(AC
11V)
Power Transformer
(l)-Secondary
(AC
120V)
Power
Transformer
(2)-Primary
(AC
120V)
Power
Transformer
(2)-Secondary
(AC
22V)
Damper
Solenoid
(connector
I/I)
Resistor
(connector
G/G)
Circulation
Fan (R &
BK)
Circulation
Fan (BK & Y)
Combustion
Blower
(BK & BK)
Thermistor (connector
Q/Q at
77°F)
Fuse
2A
(read
with
fuse
out)
Gas
Control
Valve
(connector
P/P)
Gas
Solenoid
Valve
(connector
UL)
Gas
Solenoid
Valve (connector
M/M)
APPROX.
OHMS
108,000
66
1.6
647
66
6.4
4,600
68
235
247.5
18
10,000
0.1
87
2,400
2,400
WARNING:
DISCONNECT HEATER FROM POWER SOURCE