MONITOR HEATING SYSTEM
Section
1:
Description
1-4
MANUAL
GAS
VALVE
The
Manual
Gas
Valve
is
included with Heater.
Connect
the
Manual
Gas
Valve
to gas
inlet
at
rear
of
the
cabinet.
Connection
must
be
checked
for
gas-tightness
by
means
of
leak
detector solution, soap
and
water,
or an
equivalent nonflammable solution,
as
applicable.
Figure
1 -1
1-5
AUTOMATIC
GAS
VALVE
The
Automatic
Gas
Valve
is a
normally closed
two-stage,
electro/mechanical device which
either
allows
gas to
flow
to the
burner
or
prevents
it
from
doing
so.
When
the
valve
is
energized,
a
spring-loaded
plunger
is
lifted
to
permit
the
flow
of
gas.
Removing power from
the
valve
drops
the
plunger down into
the
inlet
to
prevent
gas
from
passing through.
Coil
Spring
Body
Valve
1-6 GAS
CONTROL
VALVE
The Gas
Control
Valve
provides constant
gas
pressure
(volume)
of two
modes (High, Low)
to
the
burner.
Operation
of the Gas
Control
Valve
is
controlled
by
the
Microprocessor.
The
specifications
of the Gas
Control
Valve
are
as
follows:
Type
of gas
Natural
LP
Inlet
Gas
Supply
7.0
11.0
Pressure
(in
W.C.)
Manifold 3.15 1.34 3.19 1.42
Pressure
(in
W.C.)
Burn Mode High
Low
High
Low
Adjusting
Screw
Diaphragm
Body
Figure
1 -2
Manifold pressure
can be
cheked
by
removing
brass
fitting from
end of Gas
Control
Valve
and
inserting
a
guage with
1/8 NPT
fitting.
Figure
1 -3
Page view 3